Contact

Chlorine 2.5, liquefied under pressure

liquefied under pressure
Purity 99,5 vol.%
Descriptions Chlorine 2.5
Delivery formats In steel cylinders
Cylinders/container volumes 2 l 10 l 2 l 10 l
Content Content (kg) 2,5 12,5 2,5 12,5
Vapour Pressure Vapour Pressure (bar) 5,8 5,8 5,8 5,8

Unless otherwise stated, these refer to vapour pressure at 288,15K (15°C) and to content at 288,15K (15°C) and 1,013 bar.

Unless otherwise stated, these refer to vapour pressure at 288,15K (15°C) and to content at 288,15K (15°C) and 1,013 bar.

Properties toxic , irritant , dangerous to the environment
Valve connection DIN 477 No. 8 | (1)
Shoulder colour zinc yellow (RAL 1018)

Conversions

m3 kg l liquefied
1 at 288.15 K (15°C); 1 bar 1,000 2,998 1,919
1 kg 0,334 1,000 0,640
1 l liquid at T boiling point; 1 bar 0,521 1,562 1,000

Other delivery formats

on request

Physical Data

Molar mass 70,91 g mol-1
Liquid State
Boiling Point 239,05 (-34,1) K (°C)
Heat of Evaporation 288,05 kJ kg-1
Liquid Density 1562,5 kg m-3
Gaseous state
Density (at 273.15 K and 1.013 bar) 3,21 kg m-3
Density Ratio to Air (at 288.15 K and 1.013 bar) 2,48
Specific heat (at 298.15 K and 1.013 bar) 0,47 kJ kg-1 K-1
Thermal Conductivity (at 288.15 K and 1.013 bar) 0,0085 J s-1 m-1 K-1
Critical Point
Temperature 417,15 (144,0) K (°C)
Pressure 77,0 bar
Density 573 kg m-3
Triple Point
Temperature 172,2 (-101,0) K (°C)
Vapour Pressure 0,0140 bar
Heat of Fusion 90,4 kJ kg-1
Additional operating figures
Ignition Point -- K (°C)
Ignition Range in Air -- vol.%
Calorific Value to DIN 51850 -- kJ kg-3

Typical applications

Suitable pressure regulators:

WEGA range: see brochure: "Good on Top: Pressure Regulators for Specialty Gases". WEGA range: see brochure: "Good on Top: Pressure Regulators for Specialty Gases".
Back